A Hydrocyclone filter uses centrifugal force to seperate heavier particles from lighter particles. The tangential nozzle at the top induces a whirl which creates a centrifugal force. The heavy debris particles are pushed to the side walls and the lighter clean liquid flows out through the top outlet Nozzle. Filtration is further enhanced by the conical body which further accelerates the flow and increases centrifugal force.
| Line Size B | Min Flow | MaxFlow | D | C | L | T | H1 | H2 | W | H3 |
|---|---|---|---|---|---|---|---|---|---|---|
| nb | lpm | lpm | nb | nb | mm | mm | mm | mm | nb | mm |
| 20 | 35 | 60 | 75 | 20 | 120 | 32 | 260 | 325 | 250 | 150 |
| 25 | 36 | 125 | 100 | 25 | 150 | 40 | 330 | 400 | 250 | 150 |
| 40 | 126 | 200 | 150 | 40 | 235 | 65 | 495 | 545 | 350 | 200 |
| 50 | 201 | 285 | 200 | 50 | 300 | 75 | 580 | 615 | 350 | 200 |
| 80 | 286 | 570 | 250 | 80 | 300 | 105 | 675 | 735 | 550 | 790 |
| 100 | 287 | 1370 | 400 | 150 | 595 | 130 | 875 | 1480 | 750 | 890 |
| 150 | 1371 | 2660 | 500 | 200 | 595 | 165 | 1150 | 1610 | 750 | 1370 |
| 150 | 2661 | 3800 | 600 | 200 | 595 | 215 | 1405 | 1860 | 750 | 1370 |
| 200 | 3801 | 6080 | 750 | 200 | 700 | 265 | 1940 | 2210 | 750 | 1370 |
NOTE: The Micron chart is based on sand with a specific gravity of 2.7 gr/cm.